J Intensive Care Soc ; 24(1): 71-77, 2023 Feb.
Article in English | MEDLINE | ID: covidwho-2257912

ABSTRACT

Background: The Covid-19 pandemic has highlighted weaknesses in the National Health Service critical care provision including both capacity and infrastructure. Traditionally, healthcare workspaces have failed to fully incorporate Human-Centred Design principles resulting in environments that negatively affect the efficacy of task completion, patient safety and staff wellbeing. In the summer of 2020, we received funds for the urgent construction of a Covid-19 secure critical care facility. The aim of this project was to design a pandemic resilient facility centred around both staff and patient requirements and safety, within the available footprint. Methods: We developed a simulation exercise, underpinned by Human-Centred Design principles, to evaluate intensive care designs through Build Mapping, Tasks Analysis and Qualitative data. Build Mapping involved taping out sections of the design and mocking up with equipment. Task Analysis and qualitative data were collected following task completion. Results: 56 participants completed the build simulation exercise generating 141 design suggestions (69 task related, 56 patient and relative related, 16 staff related). Suggestions translated to 18 multilevel design improvements; five significant structural changes (Macro level) including wall moves and lift size change. Minor improvements were made at a Meso and Micro design level. Critical care design drivers identified included functional drivers (visibility, Covid-19 secure environment, workflow, and task efficiency) and behavioural drivers (learning and development, light, humanising intensive care and design consistency). Conclusion: Success of clinical tasks, infection control, patient safety and staff/patient wellbeing are highly dependent on clinical environments. Primarily, we have improved clinical design by focusing on user requirements. Secondly, we developed a replicable approach to exploring healthcare build plans revealing significant design changes, that may have only been identified once built.

2.
Wellcome Open Res ; 7: 39, 2022.
Article in English | MEDLINE | ID: covidwho-2025560

ABSTRACT

Background: The COVID-19 pandemic has accelerated adoption of remote consulting in healthcare. Despite opportunities posed by telemedicine, most hypertension services in Europe have suspended ambulatory blood pressure monitoring (ABPM). Methods: We examined the process and performance of remotely delivered ABPM using two methodologies: firstly, a Failure Modes and Effects Analysis (FMEA) and secondly, a quantitative analysis comparing ABPM data from a subgroup of 65 participants of the Screening for Hypertension in the INpatient Environment (SHINE) diagnostic accuracy study. The FMEA was performed over seven sessions from February to March 2021, with a multidisciplinary team comprising a patient representative, a research coordinator with technical expertise and four research clinicians. Results: The FMEA identified a single high-risk step in the remote ABPM process. This was cleaning of monitoring equipment in the context of the COVID-19 pandemic, unrelated to the remote setting. A total of 14 participants were scheduled for face-to-face ABPM appointments, before the UK March 2020 COVID-19 lockdown; 62 were scheduled for remote ABPM appointments since emergence of the COVID-19 pandemic between November 2020 and August 2021. A total of 65 (88%) participants completed ABPMs; all obtained sufficient successful measurements for interpretation. For the 10 participants who completed face-to-face ABPM, there were 402 attempted ABPM measurements and 361 (89%) were successful. For the 55 participants who completed remote ABPM, there were 2516 attempted measurements and 2114 (88%) were successful. There was no significant difference in the mean per-participant error rate between face-to-face (0.100, SD 0.009) and remote (0.143, SD 0.132) cohorts (95% CI for the difference -0.125 to 0.045 and two-tailed P-value 0.353). Conclusions: We have demonstrated that ABPM can be safely and appropriately provided in the community remotely and without face-to-face contact, using video technology for remote fitting appointments, alongside courier services for delivery of equipment to participants.

3.
Wellcome open research ; 7, 2022.
Article in English | EuropePMC | ID: covidwho-2010831

ABSTRACT

Background: The COVID-19 pandemic has accelerated adoption of remote consulting in healthcare. Despite opportunities posed by telemedicine, most hypertension services in Europe have suspended ambulatory blood pressure monitoring (ABPM). Methods: We examined the process and performance of remotely delivered ABPM using two methodologies: firstly, a Failure Modes and Effects Analysis (FMEA) and secondly, a quantitative analysis comparing ABPM data from a subgroup of 65 participants of the Screening for Hypertension in the INpatient Environment (SHINE) diagnostic accuracy study. The FMEA was performed over seven sessions from February to March 2021, with a multidisciplinary team comprising a patient representative, a research coordinator with technical expertise and four research clinicians. Results: The FMEA identified a single high-risk step in the remote ABPM process. This was cleaning of monitoring equipment in the context of the COVID-19 pandemic, unrelated to the remote setting. A total of 14 participants were scheduled for face-to-face ABPM appointments, before the UK March 2020 COVID-19 lockdown;62 were scheduled for remote ABPM appointments since emergence of the COVID-19 pandemic between November 2020 and August 2021. A total of 65 (88%) participants completed ABPMs;all obtained sufficient successful measurements for interpretation. For the 10 participants who completed face-to-face ABPM, there were 402 attempted ABPM measurements and 361 (89%) were successful. For the 55 participants who completed remote ABPM, there were 2516 attempted measurements and 2214 (88%) were successful. There was no significant difference in the mean per-participant error rate between face-to-face (0.100, SD 0.009) and remote (0.143, SD 0.132) cohorts (95% CI for the difference -0.125 to 0.045 and two-tailed P-value 0.353). Conclusions: We have demonstrated that ABPM can be safely and appropriately provided in the community remotely and without face-to-face contact, using video technology for remote fitting appointments, alongside courier services for delivery of equipment to participants.

4.
J Med Internet Res ; 24(2): e28890, 2022 02 15.
Article in English | MEDLINE | ID: covidwho-1686308

ABSTRACT

BACKGROUND: Commercially available wearable (ambulatory) pulse oximeters have been recommended as a method for managing patients at risk of physiological deterioration, such as active patients with COVID-19 disease receiving care in hospital isolation rooms; however, their reliability in usual hospital settings is not known. OBJECTIVE: We report the performance of wearable pulse oximeters in a simulated clinical setting when challenged by motion and low levels of arterial blood oxygen saturation (SaO2). METHODS: The performance of 1 wrist-worn (Wavelet) and 3 finger-worn (CheckMe O2+, AP-20, and WristOx2 3150) wearable, wireless transmission-mode pulse oximeters was evaluated. For this, 7 motion tasks were performed: at rest, sit-to-stand, tapping, rubbing, drinking, turning pages, and using a tablet. Hypoxia exposure followed, in which inspired gases were adjusted to achieve decreasing SaO2 levels at 100%, 95%, 90%, 87%, 85%, 83%, and 80%. Peripheral oxygen saturation (SpO2) estimates were compared with simultaneous SaO2 samples to calculate the root-mean-square error (RMSE). The area under the receiver operating characteristic curve was used to analyze the detection of hypoxemia (ie, SaO2<90%). RESULTS: SpO2 estimates matching 215 SaO2 samples in both study phases, from 33 participants, were analyzed. Tapping, rubbing, turning pages, and using a tablet degraded SpO2 estimation (RMSE>4% for at least 1 device). All finger-worn pulse oximeters detected hypoxemia, with an overall sensitivity of ≥0.87 and specificity of ≥0.80, comparable to that of the Philips MX450 pulse oximeter. CONCLUSIONS: The SpO2 accuracy of wearable finger-worn pulse oximeters was within that required by the International Organization for Standardization guidelines. Performance was degraded by motion, but all pulse oximeters could detect hypoxemia. Our findings support the use of wearable, wireless transmission-mode pulse oximeters to detect the onset of clinical deterioration in hospital settings. TRIAL REGISTRATION: ISRCTN Registry 61535692; http://www.isrctn.com/ISRCTN61535692. INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): RR2-10.1136/bmjopen-2019-034404.


Subject(s)
COVID-19 , Wearable Electronic Devices , Humans , Hypoxia/diagnosis , Oximetry , Reproducibility of Results , SARS-CoV-2